Analysis of concrete structures with composite reinforcement

In LIRA-SAPR 2018 it is possible to analyse the fibre-reinforced polymer (FRP) rebars according to DSTU-H B V.2.6-185:2012. Analysis of reinforcement is carried out according to DBN V.2.6-98:2009.

May 22, 2018

In LIRA-SAPR 2018 it is possible to analyse the fibre-reinforced polymer (FRP) rebars according to DSTU-H B V.2.6-185:2012. Analysis of reinforcement is carried out according to DBN V.2.6-98:2009.  

In analysis of reinforcement, the following classes of fibre-reinforced polymer (FRP) rebars are available: ANPB 800 and ANPB 1000. They may be used only as longitudinal reinforcement. In this case, steel reinforcement is used as transverse one.

Fibre-reinforced polymer (FRP) rebars input data.jpg

Fibre-reinforced polymer (FRP) rebars: input data


Fibre-reinforced polymer (FRP) rebars: output data

Analysis of FRP rebars is available for all types of standard sections: rectangular bar, T-section with table at the top, T-section with table at the bottom, I-section, channel, box, ring, beam, circle, cross, angle sections, asymmetric T-section with table at the top, asymmetric T-section with table at the bottom.

Analysis of FRP rebars is also available for plate elements such as shells, slabs, wall-beams.

Analysis of RC structures with FRP rebars is carried out according to SP 63.13330.2012. Concrete and reinforced concrete structures. General rules. Appendix L. (R2)

Back to the list